
THE NEUROCATCH®
PLATFORM
Our innovations in cloud-based hardware and user experience make NeuroCatch® our most powerful objective evaluation of cognitive function yet, which is delivered in minutes at the point of care.
Our next generation NeuroCatch® provides innovative features and benefits such as:


Rapid, objective, and physiological cognitive reporting providing sensitive digital measures of cognitive function for key areas of brain health



An automated, standardized, and instant report with embedded data quality checks, allowing for results evaluation and easy integration into any cognitive brain health evaluation





* EPiO = Evoked Potential Input/Output™
the power of the EPIO™
Current cognitive assessments are subjective and therefore prone to inaccurate measurements. The NeuroCatch® Platform takes ERPs to the next level with the Evoked Potential Input/Output (EPiO)™ adapter, a breakthrough technology that provides a 10-15x times improvement in temporal precision for performance gains, such as:
- Unmatched sensitivity to subtle changes in cognitive processing[3]
- Novel and unparalleled detection of Brain Response Variability™
Our EPiO™ technology allows us to capture millisecond brain waves with near-zero measurement inaccuracy. By contrast, the temporal precision of all other systems is blurred by +/-10-15 ms timing error in trigger jitter.[4]
The EPiO™ innovation effectively provides the sharpest possible snapshot of cognitive brain function. This means no more low-quality, blurry, insensitive recording of cognitive brain processing!





The NeuroCatch® Platform captures cognitive brain responses at an unprecedented level of accuracy and precision as depicted by the dramatic reduction in data noise.

THE NEUROCATCH®
PLATFORM REPORT
NeuroCatch® is an invaluable cognitive measurement tool that can help make better clinical and therapeutic decisions based on greatly enhanced cognitive evaluation capabilities.[5]
NeuroCatch® data processing software takes selected electroencephalography (EEG) scan data, processes it, and uses a proprietary algorithm to identify three distinct peaks in the event-related potential (ERP) data:

Report Variations of Radar Plots
[A-C] Three complete radar plot results showing a near-hexagonal shape. [D] A radar plot with an out of normative range measurement. [E] An incomplete radar plot resulting from the absence of a response, noise, incorrect data collection, etc. [F] A multi-scan report radar plot.A

B


D



[5] Gawryluk, J. R., D'Arcy, R. C., Connolly, J. F., & Weaver, D. F. (2010). Improving the clinical assessment of consciousness with advances in electrophysiological and neuroimaging techniques. BMC neurology, 10, 11. https://doi.org/10.1186/1471-2377-10-11
