Image


THE NEUROCATCH®
PLATFORM


NeuroCatch® innovations have launched into the cloud with a hardware platform expansion, a ramped-up user experience interface (UX), amped-up analytics under the hood, the much-anticipated intuitive report, and a surprise technology reveal that is predicted to bring unparalleled timing precision and sensitivity to changes in cognitive processing.[1],[2]




FEATURES AND BENEFITS

Our innovations in cloud-based hardware and user experience make NeuroCatch® our most powerful objective evaluation of cognitive function yet, which is delivered in minutes at the point of care.

Our next generation NeuroCatch® provides innovative features and benefits such as:

Image
Significantly enhanced accuracy and precision, overcoming the variability in subjective and inconsistent cognitive assessments[3]
Image

Rapid, objective, and physiological cognitive reporting providing sensitive digital measures of cognitive function for key areas of brain health

Image
A novel Brain Response Variability™ measurement that is a game-changer in neuro-focused patient treatment and research
Image
A cloud-based platform providing real-time access to secure, intuitive NCP Radar Plots™ visual results together with comprehensive normative data displays
Image

An automated, standardized, and instant report with embedded data quality checks, allowing for results evaluation and easy integration into any cognitive brain health evaluation

Image
An innovative EPiO™ Adapter* providing 10-15x improvement in temporal precision for unparalleled sensitivity to changes in cognitive brain responses, enabling the highest possible quality results[3]
Image
A deployable digital health technology that can be applied at any point of care across diverse settings where professional healthcare and clinical research is conducted
Image
A user management and client management software application, allowing users to seamlessly manage their relationships with new and existing clients
Image
Automated and immediate data processing to convert raw EEG brain wave data into the highest quality evoked brain response measurement possible[3]
Image
The ability to generate a single-scan report to compare results to reference range, and multi-scan reports to compare results to prior results of the same client as well as reference range

* EPiO = Evoked Potential Input/Output™


the power of
the EPIO


Current cognitive assessments are subjective and therefore prone to inaccurate measurements. The NeuroCatch® Platform takes ERPs to the next level with the Evoked Potential Input/Output (EPiO) adapter, a breakthrough technology that provides a 10-15x times improvement in temporal precision for performance gains, such as:

  • Unmatched sensitivity to subtle changes in cognitive processing[3]

  • Novel and unparalleled detection of Brain Response Variability

Our EPiO™ technology allows us to capture millisecond brain waves with near-zero measurement inaccuracy. By contrast, the temporal precision of all other systems is blurred by +/-10-15 ms timing error in trigger jitter.[4]

The EPiO™ innovation effectively provides the sharpest possible snapshot of cognitive brain function. This means no more low-quality, blurry, insensitive recording of cognitive brain processing!


Image
Image
Image
Image

Image

The NeuroCatch® Platform captures cognitive brain responses at an unprecedented level of accuracy and precision as depicted by the dramatic reduction in data noise.

Image

THE NEUROCATCH®
PLATFORM REPORT


NeuroCatch® is an invaluable cognitive measurement tool that can help make better clinical and therapeutic decisions based on greatly enhanced cognitive evaluation capabilities.[5]

NeuroCatch® data processing software takes selected electroencephalography (EEG) scan data, processes it, and uses a proprietary algorithm to identify three distinct peaks in the event-related potential (ERP) data:

  • Auditory Sensation [N100]
  • Basic Attention [P300]
  • Cognitive Processing [N400]
A detailed report then provides a user-friendly summary of the quantified results and scores is generated immediately after a NeuroCatch® scan.
Image
Report Variations of Radar Plots
[A-C] Three complete radar plot results showing a near-hexagonal shape. [D] A radar plot with an out of normative range measurement. [E] An incomplete radar plot resulting from the absence of a response, noise, incorrect data collection, etc. [F] A multi-scan report radar plot.

A

Image

B

Image
C
Image

D

Image
E
Image
F
Image
GET A SAMPLE REPORT

Please complete this form to receive a sample NeuroCatch® scan report.
FOOTNOTES
[1] The Neurocatch® Platform is a medical device registered with the U.S. Food & Drug Administration. FDA Device Listing: D476519.

[2] The NeuroCatch® Platform is intended for the elicitation, acquisition, analysis, storage, reporting, and management of electroencephalograph (EEG) and event-related potential (ERP) information to aid in assessment of cognitive function of an individual. It is intended to be operated, and the report interpreted by a clinical specialist. It is intended to be used in a professional healthcare facility environment.

[3] Hill, N. J., Mooney, S., & Prusky, G. T. (2021). audiomath: A neuroscientist's sound toolkit. Heliyon7(2), e06236. doi.org/10.1016/j.heliyon.2021.e06236

[4] The EPiO™ Adapter reduces trigger timing to the temporal resolution of the sampling rate. Currently, the NeuroCatch® sampling rate is 500 hz, so the temporal resolution is 2 ms.

[5] Gawryluk, J. R., D'Arcy, R. C., Connolly, J. F., & Weaver, D. F. (2010). Improving the clinical assessment of consciousness with advances in electrophysiological and neuroimaging techniquesBMC neurology10, 11. https://doi.org/10.1186/1471-2377-10-11